info@hydraulicstore.com  /  800-323-5749  /  Hours: 7:30am-5:00pm CT (Mon-Fri)  /  Shipping available for: Shipping available for United States Shipping available for Canada
1-1/4" 14 Tooth Splined Shaft 2.44" Long - SAE C, Vickers Replacement Pumps

1-1/4" 14 Tooth Splined Shaft 2.44" Long - SAE C, Vickers Replacement Pumps

  • Low Noise Characteristics
  • 10 Vane Systems - Low Amplitude Flow Pulsations
  • Long Life
  • Inlet and outlet ports can be oriented in four different positions relative to each other

*** Slide table left/right to view more ***

Item Order Qty. Mfr. Number Rotation In3 Per Rev. GPM @ RPM 1200 Max PSI Max RPM Inlet Outlet Port Orientation Shaft
45V42A11A22R Vickers Replacement, Hydraulic pump fixed vane 8.41 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is on opposite side of the inlet when viewed from the cover end of the pump, Vickers Replacement 45V42A11A22R

6301249

45V42A11A22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V42A11A22R CW 8.41 42 2500 1800 #48 code 61 #24 code 61 Outlet Opposite Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V50A11A22R Vickers Replacement, Hydraulic pump fixed vane 9.85 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is on opposite side of the inlet when viewed from the cover end of the pump, Vickers Replacement 45V50A11A22R

6301251

45V50A11A22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V50A11A22R CW 9.85 50 2500 1800 #48 code 61 #24 code 61 Outlet Opposite Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V60A11A22R Vickers Replacement, Hydraulic pump fixed vane 11.75 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is on opposite side of the inlet when viewed from the cover end of the pump, Vickers Replacement 45V60A11A22R

6301252

45V60A11A22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V60A11A22R CW 11.8 60 2500 1800 #48 code 61 #24 code 61 Outlet Opposite Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V42A11A22L Vickers Replacement, Hydraulic pump fixed vane 8.41 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CCW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is on opposite side of the inlet when viewed from the cover end of the pump, Vickers Replacement 45V42A11A22L

6301253

45V42A11A22L Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V42A11A22L CCW 8.41 42 2500 1800 #48 code 61 #24 code 61 Outlet Opposite Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V50A11A22L Vickers Replacement, Hydraulic pump fixed vane 9.85 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CCW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is on opposite side of the inlet when viewed from the cover end of the pump, Vickers Replacement 45V50A11A22L

6301255

45V50A11A22L Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V50A11A22L CCW 9.85 50 2500 1800 #48 code 61 #24 code 61 Outlet Opposite Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V60A11A22L Vickers Replacement, Hydraulic pump fixed vane 11.75 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CCW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is on opposite side of the inlet when viewed from the cover end of the pump, Vickers Replacement 45V60A11A22L

6301256

45V60A11A22L Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V60A11A22L CCW 11.8 60 2500 1800 #48 code 61 #24 code 61 Outlet Opposite Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V42A11B22R Vickers Replacement, Hydraulic pump fixed vane 8.41 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is located 90 degrees CCW from the inlet when viewed from the cover end of the pump, Vickers Replacement 45V42A11B22R

6301265

45V42A11B22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V42A11B22R CW 8.41 42 2500 1800 #48 code 61 #24 code 61 Outlet 90 Deg CCW from Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V50A11B22R Vickers Replacement, Hydraulic pump fixed vane 9.85 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is located 90 degrees CCW from the inlet when viewed from the cover end of the pump, Vickers Replacement 45V50A11B22R

6301267

45V50A11B22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V50A11B22R CW 9.85 50 2500 1800 #48 code 61 #24 code 61 Outlet 90 Deg CCW from Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V60A11B22R Vickers Replacement, Hydraulic pump fixed vane 11.75 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is located 90 degrees CCW from the inlet when viewed from the cover end of the pump, Vickers Replacement 45V60A11B22R

6301268

45V60A11B22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V60A11B22R CW 11.8 60 2500 1800 #48 code 61 #24 code 61 Outlet 90 Deg CCW from Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V42A11B22L Vickers Replacement, Hydraulic pump fixed vane 8.41 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CCW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is located 90 degrees CCW from the inlet when viewed from the cover end of the pump, Vickers Replacement 45V42A11B22L

6301269

45V42A11B22L Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V42A11B22L CCW 8.41 42 2500 1800 #48 code 61 #24 code 61 Outlet 90 Deg CCW from Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V50A11B22L Vickers Replacement, Hydraulic pump fixed vane 9.85 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CCW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is located 90 degrees CCW from the inlet when viewed from the cover end of the pump, Vickers Replacement 45V50A11B22L

6301271

45V50A11B22L Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V50A11B22L CCW 9.85 50 2500 1800 #48 code 61 #24 code 61 Outlet 90 Deg CCW from Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V60A11B22L Vickers Replacement, Hydraulic pump fixed vane 11.75 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CCW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet is located 90 degrees CCW from the inlet when viewed from the cover end of the pump, Vickers Replacement 45V60A11B22L

6301272

45V60A11B22L Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V60A11B22L CCW 11.8 60 2500 1800 #48 code 61 #24 code 61 Outlet 90 Deg CCW from Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V42A11C22R Vickers Replacement, Hydraulic pump fixed vane 8.41 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet in inline and on the same side as the inlet when viewed from the cover end of the pump, Vickers Replacement 45V42A11C22R

6301281

45V42A11C22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V42A11C22R CW 8.41 42 2500 1800 #48 code 61 #24 code 61 Outlet In Line with Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V50A11C22R Vickers Replacement, Hydraulic pump fixed vane 9.85 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet in inline and on the same side as the inlet when viewed from the cover end of the pump, Vickers Replacement 45V50A11C22R

6301283

45V50A11C22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V50A11C22R CW 9.85 50 2500 1800 #48 code 61 #24 code 61 Outlet In Line with Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft
45V60A11C22R Vickers Replacement, Hydraulic pump fixed vane 11.75 in3 displacement, Mount is standard SAE-C 2-bolt flange 1-1/4"-14 spline X 2.44" long shaft (includes pilot length), Pilot diameter is 5.00", 2500 PSI maximum, 1800 RPM maximum, CW rotation, #48 code 61 inlet, #24 code 61 outlet, Outlet in inline and on the same side as the inlet when viewed from the cover end of the pump, Vickers Replacement 45V60A11C22R

6301284

45V60A11C22R Vickers Replacement, Hydraulic...

$1,108.80/each

Ships next business day

45V60A11C22R CW 11.8 60 2500 1800 #48 code 61 #24 code 61 Outlet In Line with Inlet 1-1/4" - 14 Splined x 2.44" Length Splined Shaft